Effect of Strength and Fiber Reinforcement on Fire Resistance of High-Strength Concrete Columns

Venkatesh Kodur, Fu-Ping Cheng, Tien-Chih Wang, Mohamed A. Sultan

Journal of Structural Engineering · 2003 · 232 citations · 4 references

DOIFull text

Open access

Concepts

Abstract

In this paper, results from fire resistance experiments on five types of reinforced concrete columns are presented. The variables considered in the study include concrete strength [normal-strength concrete (NSC) and high-strength concrete (HSC)], aggregate type (siliceous and carbonate aggregate), and fiber reinforcement (steel and polypropylene fibers). Data from the study is used to determine the structural behavior of HSC columns at elevated temperatures. A comparison is made of the fire resistance performance of HSC columns with that of NSC and fiber-reinforced HSC columns. The factors that influence the thermal and structural behavior of HSC concrete columns under fire conditions are discussed. The results show that the fire resistance of a NSC column is higher than that of a HSC column. Also, the addition of polypropylene fibers and the use of carbonate aggregate improve fire resistance.

References