The Journal of Infectious Diseases · 2012 · 186 citations · 12 references
Life SciencesImmunologyInfectious DiseasesHepatologyMolecular VirologyVirologyAntigen Detection AssaysSerological DiagnosticsSerum Specific Immunoglobulin E TestingViral DiagnosticsViral EpidemiologyViral HepatitisDiagnostic SensitivityHepatitis E Virus InfectionHepatitis SerologyHepatitis Virus SerologySensitivityTest Performance CharacteristicsTest Performance EffectsVirus Detection Assays
Hepatitis E virus (HEV) seroprevalences of 0.3%-53% were reported from industrialized countries. Because these estimates may be influenced by detection assays, this study compares 3 frequently used tests for HEV detection: the MP Diagnostics HEV immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA), the Axiom Diagnostics HEV IgG enzyme immunoassay (EIA), and the Mikrogen recomLine HEV IgG assay. Sera from 200 healthy healthcare workers and 30 individuals with acute HEV infection were analyzed. Among the healthy individuals, HEV IgG was found in 4.5% by the MP Diagnostics assay, in 29.5% by the Axiom Diagnostics assay, and in 18% by the Mikrogen assay. Among individuals with acute HEV infection, positive results were obtained for 83.3%, 100%, and 96.7%, respectively. Thus, the 3 assays show clear differences in diagnostic sensitivity.
12
Hepatitis E Virus Antibodies in Blood Donors, France
Jean‐Michel Mansuy, Richard Bendall, Florence Abravanel et al. · Emerging infectious diseases · 2011 · 362 citations · Full text
George G. Schlauder, David L. Smalley, Jon E. Rosenblatt et al. · Journal of General Virology · 1998 · 332 citations