Antimicrobial Agents and Chemotherapy · 2009 · 66 citations · 20 references
Life SciencesInfectious DiseasesMicrobiologyAntimicrobial ResistanceBacteriologyMedical MicrobiologyAntibacterial ResistanceAntibiotic ResistanceAntibiotic Resistance MechanismsBacterial InfectionsResistance In Gram-positive BacteriaClarithromycin ResistanceMacrolide Resistance GenesMacrolide Resistance MechanismsMacrolide TherapyPathogen Resistance TestingPneumococcal DiseaseResistance Mechanisms In StreptococciStreptococcus Species
CEM-101 had MIC ranges of 0.002 to 0.016 microg/ml against macrolide-susceptible pneumococci and 0.004 to 1 microg/ml against macrolide-resistant phenotypes. Only 3 strains with erm(B), with or without mef(A), had CEM-101 MICs of 1 microg/ml, and 218/221 strains had CEM-101 MICs of <or=0.5 microg/ml. CEM-101 MICs were as much as 4-fold lower than telithromycin MICs against all strains. For Streptococcus pyogenes, CEM-101 MICs ranged from 0.008 to 0.03 microg/ml against macrolide-susceptible strains and from 0.015 to 1 microg/ml against macrolide-resistant strains. Against erm(B) strains, erythromycin, azithromycin, and clarithromycin MICs were 32 to >64 microg/ml, while 17/19 strains had telithromycin MICs of 4 to 16 microg/ml; CEM-101 MICs were 0.015 to 1 microg/ml. By comparison, erm(A) and mef(A) strains had CEM-101 MICs of 0.015 to 0.5 microg/ml, clindamycin and telithromycin MICs of <or=1 microg/ml, and erythromycin, azithromycin, and clarithromycin MICs of 0.5 to >64 microg/ml. Pneumococcal multistep resistance studies showed that although CEM-101 yielded clones with higher MICs for all eight strains tested, seven of eight strains had clones with CEM-101 MICs that rose from 0.004 to 0.03 microg/ml (parental strains) to 0.06 to 0.5 microg/ml (resistant clones); for only one erm(B) mef(A) strain with a parental MIC of 1 microg/ml was there a resistant clone with a MIC of 32 microg/ml, with no detectable mutations in the L4, L22, or 23S rRNA sequence. Among two of five S. pyogenes strains tested, CEM-101 MICs rose from 0.03 to 0.25 microg/ml, and only for the one strain with erm(B) did CEM-101 MICs rise from 1 to 8 microg/ml, with no changes occurring in any macrolide resistance determinant. CEM-101 had low MICs as well as low potential for the selection of resistant mutants, independent of bacterial species or resistance phenotypes in pneumococci and S. pyogenes.
20
Performance standards for antimicrobial susceptibility testing
Mary Jane Ferraro · 2001 · 9.8K citations
Matthew R. Moore, Robert E. Gertz, Robyn L. Woodbury et al. · The Journal of Infectious Diseases · 2008 · 485 citations · Full text
Veterinary Medicine, Infectious Diseases, Infectious Disease Epidemiology +12
Michael R. Jacobs · Journal of Antimicrobial Chemotherapy · 2003 · 468 citations · Full text