Development of a method to measure methadone enantiomers and its metabolites without enantiomer standard compounds for the plasma of methadone maintenance patients

Sheng‐Chang Wang, Ing‐Kang Ho, Shiow‐Ling Wu, Shu Chih Liu, Hsiang‐Wei Kuo, Keh‐Ming Lin, Yu‐Li Liu

Biomedical Chromatography · 2009 · 25 citations · 19 references

Concepts

Abstract

A liquid chromatography-photodiode array (LC-PDA) method using a chiral analytical column was developed to determine the plasma levels of enantiomers of methadone and its chiral metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), without the standard compounds of R-form or S-form enantiomers. This method was established by the characteristics of recombinant cytochrome P-450 (CYP) isozymes, where CYP2C19 prefers to metabolize R-methadone and CYP2B6 prefers to metabolize S-methadone. We incubated the racemic methadone standard with either enzyme for 24 h. We identified the retention times of R- and S-methadone to be around 10.72 and 14.46 min, respectively. Furthermore, we determined the retention times of R- and S-EDDP to be approximately 6.76 and 7.72 min, respectively. No interferences were shown through the retention times of morphine, buprenorphine and diazepam. With the high recovery rate of a solid-phase extraction procedure, this method was applied in analyzing plasma concentrations of seven methadone maintenance patients where R- and S-methadone and R- and S-EDDP were 233.4 +/- 154.9 and 185.9 +/- 136.3 ng/mL and 84.4 +/- 99.4 and 37.6 +/- 22.9 ng/mL, respectively. These data suggest that the present method can be applied for routine assay for plasma methadone and EDDP concentrations for patients under treatment.

References

19