IEEE Transactions on Instrumentation and Measurement · 1991 · 12 citations · 5 references
EngineeringElectrical EngineeringAnalog ElectronicsInstrumentationPower ElectronicsAc-dc ConversionAc-dc ConvertersCalibrationDc-dc ConvertersEquipment CalibrationSensor CalibrationAccuracyCalibration TechniquesFeedforward Error CorrectionPhase CalibrationRange Extender Systems
High precision range extenders for high voltage (600 V) and large current (100 A) have been developed as separate units to be used with a previously developed AC calibrator 111. To obtain high accuracy and stable operation an error feed-forward technique was implemented. A current-comparator-based capacitance bridge was used for the gain and phase calibration of the high voltage range extender. A precision two stage current transformer and a very stable time-division based wattconverter were u8ed for the verification of the current range extender.
5