Experimental Biology and Medicine · 1973 · 14 citations · 0 references
PharmacyPharmacokineticsToxicologyChemical KineticsToxicodynamicsToxicokineticsAerosol ChemistryAerosol ScienceLung DepositionPulmonary ToxicityPulmonary ToxicologyRespiratory ToxicologyAerosol Chemical CompositionAerosol Physicochemical PropertiesAntimony ChemistryDrug Retention TimeInhalation Aerosol DynamicsInhalation Exposure KineticsMetabolic TracingRespirable Aerosols
The temperature of aerosol formation has been demonstrated to profoundly influence the metabolic pattern of inhaled antimony. Using 124Sb as a tracer, aerosols were nebulized from the tartrate complex and the droplets passed through heating columns at 100, 500 and 1100°, before reaching the animal. The lower temperature aerosol was more soluble and left the lung rapidly, localizing primarily in skeleton. The two higher temperature-produced aerosols resulted in 124Sb remaining in the lung for extended periods. Overall retention, regardless of the critical organ (lung or skeleton), would tend to place antimony in the class of compounds that have a retention time on the order of weeks.