IEEE Transactions on Nuclear Science · 2011 · 16 citations · 13 references
EngineeringBiomedical EngineeringNuclear EngineeringDiagnostic ImagingNuclear InstrumentationRadiation DetectionBrain ImagingDetector TechnologyMedical Imaging InstrumentationPositron Emission TomographyRadiation Imaging DetectorsScintillation DetectorsDetector Readout ElectronicsEnergy Spectra MeasurementFront-end Electronics For Detector ArraysPet Detector TechnologyPositron Emission Tomography DetectorsPositron Emission Tomography InstrumentationPositron Emission Tomography ScintillatorsScintillator Array Design
We have implemented and evaluated a positron emission tomography (PET) demonstrator using two monolithic detector blocks operating in coincidence with dedicated application-specific integrated circuit (ASIC) readout. Each detector is composed of a monolithic lutetium yttrium orthosilicate (LYSO) scintillator coupled to a pair of Hamamatsu S8550-02 APD arrays. The front-end electronics of this demonstrator is based on the VATA240 ASIC readout, which sums the charge provided by each row and column of the APD array. The ASIC has been characterized obtaining a noise per row or column less than 2000 electrons rms with the APD at its inputs and a good linear response in the range from 5 fC to 30 fC. We have acquired energy spectra of <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> Na and <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">137</sup> Cs radioactive sources, achieving energy resolutions between 13.2% and 14.1% full width at half maximum (FWHM) at 511 keV. We have estimated the interaction position over the surface of the monolithic blocks using Neural Networks (NN) position determining algorithms, obtaining spatial resolutions at the detector level down to 2.1 mm FWHM. By using this detector technology and electronics we have achieved images of point sources with spatial resolutions as good as 2.1 mm FWHM for filtered back projection (FBP) reconstructions methods with single slice rebinning (SSRB). Based on the results obtained with this demonstrator, we are developing a PET insert for existing magnetic resonance imaging (MRI) equipment, to be installed in a collaborating hospital and used for clinical PET-MRI of the human brain.
13
MR diffusion tensor spectroscopy and imaging
Peter J. Basser, James Mattiello, D. LeBihan · Biophysical Journal · 1994 · 6K citations · Full text
Medicine, Neuroscience, Radiology +12
Functional Mapping of the Human Visual Cortex by Magnetic Resonance Imaging
John W. Belliveau, David N. Kennedy, Robert C. McKinstry et al. · Science · 1991 · 1.9K citations
Medicine, Neuroscience, Physiology +17
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Martin S. Judenhofer, Hans F. Wehrl, D.F. Newport et al. · Nature Medicine · 2008 · 978 citations
Treatment of axial data in three-dimensional PET.
Margaret E. Daube-Witherspoon, G. Muehllehner · PubMed · 1987 · 356 citations