1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451) · 2002 · 15 citations · 8 references
EngineeringMaterials EngineeringMaterials ScienceHeat TransferMicroelectromechanical SystemsSensorsHumidity SensorsMems SensorsMicroelectromechanical SensorsPolymer Thin FilmsSensor MaterialsCapacitive Humidity SensingCapacitive Humidity SensorsCapacitive SensorsDesorptionHumidityInterdigitated Electrode SensorsMiniaturized Humidity SensorsResponse Time
Presents and compares two capacitive humidity sensors with interdigitated electrodes for a portable clinical application. The first structures are covered by a polyimide sensitive layer and the optimised ones include a BCB sensitive layer and a heating resistor. Humidity measurements results are presented, in particular sensors response time in absorption which are very small (inferior to 500 ms). Then, mechanisms of absorption and adsorption in a polymer layer are described and the two structures are compared. The suitability of optimised sensors for the authors' application is discussed: new structures permit to increase sensitivity and decrease response time. When the structure is maintained at 40/spl deg/C by its heater, the response time is 200 ms and the total desorption time is 11 s.
8
Fundamentals of heat and mass transfer
A. V. Larkin · BSU Digital Library (Belarusian State University) · 2018 · 8.1K citations · Full text