AIChE Journal · 1977 · 17 citations · 23 references
EngineeringBiochemistryChemical EngineeringBioseparationsSeparation ProcessesSeparation ScienceChromatographic SeparationChromatographyElectrophoretic SeparationIon-exchange ChromatographyProtein PurificationProtein SeparationBiomolecule SeparationProtein Separation TechniquesPumpingPurificationSeparation Mechanisms
Abstract A semicontinuous p H parametric pump for separating proteins was experimentally investigated using the model system haemoglobin and albumin on a Sephadex ion exchanger. The pump considered had a center feed between an enriching column and a stripping column and was operated batchwise during upflow and continuously during downflow. Various factors affecting separations were examined. It was shown that parametric pumping is capable of separating proteins with high separation factors.
23