Characteristics of heat transfer in a helium-filled disk enclosure

Isamu Sato, K. Otani, S. Oguchi, K. Hoshiya

IEEE Transactions on Components Hybrids and Manufacturing Technology · 1988 · 10 citations · 3 references

Concepts

Abstract

Experimental results of heat transfer in a helium-filled disk enclosure (DE) are reported. The windage loss of a DE containing helium was found to be 1/5 that of a DE containing air. The temperature increase of the positioner coil and spatial temperature variations in a helium-filled DE were found to be much smaller than in air. It is concluded that these results are due to the lower specific weight and higher thermal conductivity of helium.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>