Chemical Engineering & Technology · 1989 · 14 citations · 3 references
EngineeringChemical EngineeringHeat TransferProcess ControlProcess Systems EngineeringHeat Transfer ModelingTemperature ControlTemperature MeasurementThermal Control SystemsThermal ManagementColumnsMass Transfer Zone AnalysisState Observer DesignState VariablesStripping
Abstract In order to achieve optimal energy‐saving, load‐dependent operation of rectification columns, development and implementation of model‐based control concepts are necessary. This paper reports on the design and step‐by‐step testing of a state observer for the estimation of two state variables which cannot be measured directly, namely the vapour rate and the location of mass transfer zone (temperature front) in the stripping section of a production column. The procedure is described, and the relevant simulation and operation results are presented and discussed. Initial experience, gained when the concept was put into practical operation, is reported.
3