Anaphylactic reaction induced by a polysulfone/polyvinylpyrrolidone membrane in the 10th session of hemodialysis with the same dialyzer

Igor Denizarde Bacelar Marques, Karina França PINHEIRO, Lílian Pires de Freitas do Carmo, Maristela Carvalho da Costa, Hugo Abensur

Hemodialysis International · 2011 · 44 citations · 15 references

Concepts

Abstract

The majority of severe hypersensitivity reactions in hemodialysis patients have occurred due to sensitization to ethylene oxide or to nonbiocompatible membrane dialyzers. The use of polysulfone dialyzers rarely causes hypersensitivity reactions. In the present study, we describe a case of severe life-threatening reactions induced by polysulfone dialyzers (from different manufacturers subjected to a variety of sterilization methods), which occurred after 9 sessions of hemodialysis with the same prescription, exemplifying the complexity of such reactions.

References

15