Radiology · 2000 · 213 citations · 18 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyInterventional RadiologyHepatobiliary SurgeryLiver BiopsyLiver CancerLiver ImagingMagnetic Resonance ImagingTumor ImagingAblation Of Liver TumorsHepatic Tumor ImagingHepatic TumorsIntraprocedural ImagingLiver Tumor AblationLiver Tumor ImagingMagnetic ResonanceReal-time Monitoring
PURPOSE: To describe the cryoablation of liver tumors by using a percutaneous approach and intraprocedural magnetic resonance (MR) imaging monitoring and to assess the feasibility and safety of the procedure. MATERIALS AND METHODS: Fifteen hepatic tumors (mean diameter, 2.9 cm) in 12 patients were treated (18 total cryoablations). Fourteen were metastases and one was a hemangioma; all were proved at biopsy. By using a 0.5-T open MR imaging system, cryoneedles were placed and lesions ablated by using real-time monitoring. Clinical signs and symptoms were assessed and laboratory tests performed. Intraprocedural depictions of iceballs were compared with contrast material-enhanced MR imaging-based estimates of cryonecrosis that were obtained 24 hours after cryoablation. RESULTS: MR imaging-guided percutaneous cryotherapy resulted in no serious complications and no clinically important changes in serum liver enzymes or creatinine or myoglobin levels. Intraprocedural MR imaging demonstrated iceballs as sharply marginated regions of signal loss that expanded and engulfed tumors. The maximal iceball size was 4.9 x 2.2 x 2.2 cm with the use of one cryoneedle and 6.0 x 5.6 x 4.9 cm with three cryoneedles. Intraprocedural iceball depictions correlated well with postprocedural cryonecrosis estimates. CONCLUSION: MR imaging-guided percutaneous cryotherapy of liver tumors is feasible and safe. MR imaging can be used to estimate cryotherapy effects and guide therapy intraprocedurally.
18
Superconducting open-configuration MR imaging system for image-guided therapy.
John F. Schenck, F.A. Jolesz, Peter Roemer et al. · Radiology · 1995 · 437 citations
Interactive MR-guided biopsy in an open-configuration MR imaging system.
Stuart G. Silverman, B. Collick, Michael R. Figueira et al. · Radiology · 1995 · 328 citations
The process of freezing and the mechanism of damage during hepatic cryosurgery
Boris Rubinsky, C.Y. Lee, J. Bastacky et al. · Cryobiology · 1990 · 216 citations
Medicine, Surgery, Hepatology +10
Magnetic Resonance Bioeffects, Safety and Patient Management
Journal of Neuroimaging · 1995 · 155 citations