Pacing and Clinical Electrophysiology · 2005 · 122 citations · 7 references
MedicineBiomedical EngineeringCardiologyBioinstrumentationElectrophysiologyWireless CommunicationsAtrial ElectrophysiologyAtrial FibrillationCardiac PacingCardiovascular MonitoringPatient MonitoringTelemetry SystemsAtrial Fibrillation DetectionAtrial Fibrillation MonitoringCardiac Implantable DevicesHome Monitoring SystemsImplantable Bioelectronic DevicesPatient Data IntegrityRemote Cardiac MonitoringTelemetry In Healthcare
Remote telemetry may facilitate the management of implantable devices. We tested the reliability of a new automatic, wireless home monitoring (HM) system that archives data every 24 hours. We retrospectively analyzed archival data from 276 consecutive pacing system implants to define temporal atrial fibrillation (AF) patterns and associated ventricular rate. An "AF day" was defined by a >20%/24 hour mode switch (MS) duration, irrespective of the MS number. Management decisions resulting from transmissions were noted. A pilot study confirmed that 89% of 22,356 transmissions were successful, of which >90% were received in <5 minutes. Data integrity was 100% preserved. Overall, AF developed in 29 patients (10.5%), representing a total of 645 AF days (mean = 22.2 +/- 29.6 AF, median = 9 days), over 12 +/- 2 months of monitoring. AF was infrequent (<AF 30 days/year) in 80% of patients. When AF did occur, 83% patients had >/=1 day during which the AF burden was >50% of 24 hours. Ventricular rates during 645 AF days in 29 patients averaged 95.1 +/- 9.9 beats/min (median = 94 beats/min). Ventricular rates were >80 beats/min in 25 +/- 30 AF days (median = 11 days). HM enabled rapid anticoagulation decisions. In recipients of implantable devices, automatic wireless telemetry with HM was efficient and reliable. Its application may overcome some current challenges in AF management by early notification and precise measurement of both AF burden and ventricular rate during AF.
7
Impact of Atrial Fibrillation on the Risk of Death
Emelia J. Benjamin, Philip A. Wolf, Ralph B. D’Agostino et al. · Circulation · 1998 · 4.6K citations
Medicine, Cardiology, Aging +16
A Comparison of Rate Control and Rhythm Control in Patients with Atrial Fibrillation
D G Wyse, A.L. Waldo, John Dimarco et al. · New England Journal of Medicine · 2002 · 4.4K citations · Full text
DanielL Dries, D. Exner, BernardJ Gersh et al. · Journal of the American College of Cardiology · 1998 · 976 citations · Full text
Atrial High Rate Episodes Detected by Pacemaker Diagnostics Predict Death and Stroke
Taya V. Glotzer, Anne S. Hellkamp, John Zimmerman et al. · Circulation · 2003 · 753 citations · Full text