High efficiency power factor correction using interleaving techniques

Brett A. Miwa, David M. Otten, M.E. Schlecht

2003 · 362 citations · 10 references

Concepts

Abstract

A highly efficient 1.5 kW power factor correction converter for computer applications is presented. Eight boost-topology switching cells are interleaved to meet stringent EMI input ripple specifications while operating at a very low switching frequency (25 kHz per cell) to minimize switching losses. The result is a system with very high conversion efficiency (94%-97%, including input bridge, bias supply, and EMI filter losses) over the 93-264 VAC input range. Key implementation details, including discontinuous inductor current operation, a combination of linear and bang-bang control algorithms for fast dynamic load response, and extended (100 ms) power outage ride-through capability, are described.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

10