Detection of Energized Structures With an Electro-Optic Electric Field Sensor

James E. Toney, Alfonso G. Tarditi, Peter Pontius, Andrea Pollick, Sri Sriram, Stuart A. Kingsley

IEEE Sensors Journal · 2014 · 27 citations · 6 references

Concepts

Abstract

An electro-optic, solid-state electric field sensor system for noncontact detection of energized objects at power frequency (60 Hz) was investigated. In laboratory testing, the sensor system was found to have a minimum detectable field amplitude of 4 mV/m/Hz <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> , which was further reduced by a factor of 2 through vector averaging over 20 cycles. In an experimental setup emulating the realistic scenario of an energized conducting structure (such as a street light or metal fence post), the detection of a 1-m object energized at 1 VAC at a distance of 2 m was demonstrated.

References

6