IEEE Transactions on Industrial Electronics · 2010 · 116 citations · 18 references
EngineeringElectrical EngineeringElectric MachinesLow-power DesignPower ElectronicsDirect Current MachinesElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsInduction MachinesDemagnetization BehaviorDirect Torque ControlInduction MotorsLow-speed OperationLow-speed OperationsLow-speed PerformanceStator Flux ControlTorque
A novel technique that improves the low-speed performance of a five-phase induction machine (IM) driven by a two-level inverter using the classic direct torque control (DTC) technique is presented. Demagnetization of the stator flux is investigated when the IM runs at lower speeds, and a solution is provided to overcome this phenomenon. The proposed technique reduces the demagnetization phenomenon by using the ±36° displaced voltage vector during low-speed operation but employs the ±72° displaced voltage vectors otherwise. The demagnetization of the stator flux is shown by simulation and experiment to be eliminated using the proposed technique. It can be observed that the proposed technique can significantly improve the rate of change of stator flux, the torque response, and the speed response compared with traditional method.