Tentative modelling of spray‐dry scrubbing of SO<sub>2</sub>

Hans T. Karlsson, Jonas Klingspor

Chemical Engineering & Technology · 1987 · 23 citations · 3 references

Concepts

Abstract

Abstract A 0.5 MW spray‐dry scrubbing FGD pilot plant was used in the study of spray dryer performance over a wide range of operating conditions. Experimental findings were compared with a spray dryer model. During operation with large excesses of lime, the SO 2 absorption was limited by gas phase diffusion. At operation with a shortage of lime, the rate limiting step was the dissolution rate of lime. In addition, the flow regime in a spray dryer can be best described as well mixed. The SO 2 level in the flue gas was found to exert no direct effect on the efficiency of SO 2 removal. The observed effects are attributed solely to the changes in the drying process, due to the inter‐dependence of slurry composition and SO 2 concentration.

References

3