IEEE Photonics Technology Letters · 1994 · 10 citations · 6 references
EngineeringElectrical EngineeringPhysicsInstrumentationOpticsSensorsInterferometryOptical InstrumentationOptical InstrumentsOptical MetrologyOptical SensingOptical SensorsInterferometric SensorsOptical InterferometersOptical InterferometryOptical Measurement SystemsOptical ScannersOptical ScanningSensor ApplicationsWhite-light Interferometry
A white light interferometric system in sensor applications is often configured with a sensing interferometer to respond to the measurand and a receiving interferometer to recover the signal by means of a scanning system. Mechanical and electronic scans are the two techniques commonly used at present. In this paper, an optical scanning technique is presented as an alternative for sensor use with comparable performance. This technique offers the possibility of eliminating the receiving interferometer and the potential of a simple, stable and compact system.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
6
Pseudoheterodyne detection scheme for optical interferometers
D.A. Jackson, A.D. Kersey, M. Corke et al. · Electronics Letters · 1982 · 236 citations
Distance measurement by the wavelength shift of laser diode light
Hisao Kikuta, Koichi Iwata, Ryo Nagata · Applied Optics · 1986 · 164 citations
Two-wavelength fibre gyroscope with wide dynamic range
A.D. Kersey, A. Dandridge, W. K. Burns · Electronics Letters · 1986 · 33 citations