Improved acoustic coupling of air-coupled micromachined ultrasonic transducers
44
Citations
10
References
2014
Year
Unknown Venue
Acoustic CouplingEngineeringMicrofabricationUltrasonicsMechanical EngineeringPhased ArrayTransducer PrincipleEducationMaximum Transducer SizeUltrasound TransducerAcoustic TweezerComputational ElectromagneticsBiomedical EngineeringUltrasoundInstrumentationAcoustic SensorMicromachined Ultrasonic Transducer
Phased array imaging with micromachined ultrasound transducer (MUT) arrays is widely used in applications such as ranging, medical imaging, and gesture recognition. In a phased array, the maximum spacing between elements must be less than half of the wavelength to avoid large sidelobes. This places a limit on the maximum transducer size which is not attractive since the acoustic coupling drops rapidly for MUT diameters less than a wavelength. Here, we present a new approach to increase the acoustic coupling of small radius MUTs using an impedance matching resonant tube etched beneath the MUT. Impedance, laser Doppler vibrometer (LDV), and acoustic burst measurements confirm a 350% increase in SPL and 8x higher bandwidth compared to transducers without the impedance matching tube, enabling compact arrays with high fill-factor and efficiency.