2008 · 23 citations · 5 references
EngineeringMechanical EngineeringInstrumentationMicroelectromechanical SystemsSensorsCalibrationMechanical MeasurementSensor CalibrationTemperature MeasurementTemperature SensorsThermal SensorsCalibration CurvesCalibration Of Mechanical SensorsCalibration Of Temperature SensorsDynamic CalibrationTemperature CalibrationThermal Sensor CalibrationTorqueTorque Calibration
Possible ways of reducing calibration complexity are considered for a non-contact passive torque and temperature sensor based on three one-port SAW resonators working at 433-437 MHz. A spread of sensor characteristics is investigated and it is shown that dynamic calibration curves differ considerably from the static ones not allowing accelerated temperature variation during calibration. A simplified procedure is suggested using correction of generic calibration parameters based on individual sensor calibration only in one or two temperature points.
5
Non-contact torque sensors based on SAW resonators
J. Beckley, V. Kalinin, M. Lee et al. · 2003 · 80 citations
V. Kalinin, R. D. Lohr, Arthur Leigh et al. · Proceedings of the IEEE International Frequency Control Symposium · 2007 · 40 citations
Engineering, Automotive Engineering, Electrical Engineering +17