Emerging infectious diseases · 1999 · 119 citations · 6 references
Life SciencesInfectious DiseasesMicrobiologyHypersensitivityIndustrial HygieneMedical MicrobiologyHeavy Metal ContaminationHypersensitivity PneumonitisMicrobial ContaminationOccupational Exposure PreventionOccupational Health Risk AssessmentOccupational Heavy Metal ExposureRetrospective Record Review
Hypersensitivity pneumonitis (HP) in workers exposed to metal removal fluids (MRFs) is increasing. This study supports the hypothesis that aerosolized mycobacteria colonizing the MRFs likely cause the disease. Three case studies of HP outbreaks among metal workers showed potentially high exposures to a rare and newly proposed Mycobacterium species. Retrospective review of samples submitted to our laboratory showed an association between presence of mycobacteria and HP.
6