IEEE Transactions on Energy Conversion · 2006 · 26 citations · 7 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesElectromagnetismBrushless Dc MachinesCurrent-voltage CharacteristicsElectric CircuitsElectric MotorsMagnetic Circuit AnalysisMotor CircuitsCommutationsEquivalent Circuit AnalysisEquivalent Circuit ModelingMagnetic SaturationMagnetic Saturation AnalysisMagnetic Saturation EffectsMotor ModelingMutual Inductance
An equivalent electrical circuit, characterized by the minimum coil sections number necessary to analyze the commutation in a universal motor, is discovered. The model parameters are also determined: in particular, the self and mutual inductance coefficients and the electromotive force induced in the coil sections (taking into account the magnetic saturation), the brush-commutator voltage drop, the electric arc. By means of a numerical solution of the equivalent circuit, the current waveforms are analyzed; the comparison between the computed and measured waveforms of the brush-commutator voltage drops allows to verify the model.
7