IEEE Transactions on Microwave Theory and Techniques · 1955 · 19 citations · 2 references
EngineeringElectrical EngineeringInstrumentationMicroelectronicsMicrowave EngineeringDetector TechnologyElectrical MeasurementFrequency MetrologyMicrowave Integrated CircuitsMicrowave MeasurementsMicrowave Transmission LinesCoherent DetectionMicrowave Detector DesignMicrowave RadiometryMicrowave ReceiversPhase MeasurementPhase-sensitive Detection
A phase-sensitive coherent detector used for microwave laboratory measurements is described. The receiver measures the real (|E| cos alpha) and imaginary (|E| sin alpha) components of a signal E with equipment which is less elaborate than that required for measuring the amplitude |E| and phase alpha. Furthermore, many calculations are more convenient if E is presented in rectangular rather than polar form. Measurements made with the receiver on known fields in waveguides are included to demonstrate its accuracy. The receiver has a sensitivity of -125 dbw at 9,375 mc.
2
M.E. Brodwin, Craig Johnson, W. Waters · Proceedings of the IRE · 1953 · 12 citations