Acta Anaesthesiologica Scandinavica · 2012 · 11 citations · 8 references
MedicineInternal MedicineDiabetologyDialysisHemodialysisBlood Glucose MonitoringContinuous Glucose MonitoringDialyzer MembranesGlycemic MonitoringMetabolic MonitoringBland-altman PlotGlucose ConcentrationGlucose MonitoringGlucose QuantificationLaboratory Plasma Glucose TestingMicrodialysis MeasurementPeripheral Intravenous CathetersTight Glycemic Control
BACKGROUND: The benefit of tight glucose control in the intensive care unit is controversial. Part of the debate is around the frequency of glucose measurements, and therefore, a continuous glucose monitoring system is needed. Previously, we have shown that intravenous microdialysis has the potential for this purpose but that the accuracy must be improved. The aim of this study was to investigate the effects of the microdialysis membrane length and the perfusion rate on improving the accuracy. METHODS: Two volunteer studies were performed, one comparing intravenous microdialysis catheters with different lengths (10 and 20 mm) and one comparing different perfusion rates (0.5, 1 and 2 μl/min) with plasma glucose reference levels. Median values of seven samples taken over 70-min periods were compared using Bland-Altman plots. RESULTS: When microdialysis membranes of 10 and 20 mm perfused at a rate of 1 μl/min were used, the differences with measured plasma glucose levels were 30% ± 21% and 14% ± 13%. In comparison, plasma glucose measured in two different veins gave a difference of 3% ± 3%. In the second study, the differences between measured plasma glucose and that estimated with a microdialysis membrane of 30 mm perfused at 0.5, 1 and 2 μl/min were 8% ± 7%, 25% ± 19% and 39% ± 28%. Bland-Altman analyses gave the best line of equality (-0.11 mM) and the lowest limits of agreement (1.13 and -1.35 mM) when using the 30-mm membrane perfused with 0.5 μl/min. CONCLUSION: The agreement of the intravenous microdialysis with plasma glucose levels improved significantly when increasing the microdialysis membrane length, and thereby the membrane area, and decreasing the perfusion rate.
8
Intensive Insulin Therapy in Critically Ill Patients
Greet Van den Berghe, Pieter Wouters, Frank Weekers et al. · New England Journal of Medicine · 2001 · 10K citations · Full text
Intensive Insulin Therapy in the Medical ICU
Greet Van den Berghe, Alexander Wilmer, Greet Hermans et al. · New England Journal of Medicine · 2006 · 3.7K citations · Full text
Intensive Insulin Therapy and Pentastarch Resuscitation in Severe Sepsis
Frank M. Brunkhorst, Christoph Engel, Frank Bloos et al. · New England Journal of Medicine · 2008 · 2.9K citations · Full text
Jean‐Charles Preiser, Philippe Devos, Sergio Ruiz‐Santana et al. · Intensive Care Medicine · 2009 · 907 citations
Medicine, Endocrinology, Diabetology +15