Thermoluminescence Spectra of X-Ray Colored KCl Crystals

A. Halperin, N. Kristianpoller

Journal of the Optical Society of America · 1958 · 26 citations · 6 references

Concepts

Abstract

Thermoluminescence spectra of x-ray colored KCl crystals have been recorded, using a liquid-air cooled photomultiplier as detector.Glow peaks are shown to appear in pairs—a violet one (0.395 μ) and a blue one (at 0.44 μ)—repeated several times throughout the temperature range of 90–550°K.The phosphorescence at 90°K was found to be composed of three bands (at 0.51, 0.395, and about 0.28–0.35 μ). The 0.51-μ band shows two glow bursts on warming the crystal.The half-intensity breadth of the violet band (and probably also of the 0.44- and 0.51-μ bands) was found to equal that of the F band, this to include also the temperature broadening.It is suggested that the thermoluminescence arises from transitions involved in the recombination of free holes and F electrons.

References

6