Quantitative Auger electron spectroscopy of binary systems. Matrix correction

A. I. Zagorenko, V. I. Zaporozchenko

Surface and Interface Analysis · 1989 · 15 citations · 18 references

Concepts

Abstract

Abstract The matrix correction factor, M , has been determined for 1953 binary systems. The calculated M values are in the range 0.3–2.6. The probable error, with no account being taken of the matrix effect, is 30%. A study has been made of the effect on M of different methods of calculation, the experimental conditions of the analysis, the choice of the Auger lines and the concentration of the system analysed. The greatest effect on M values is the choice of equations used for calculating the escape depth of the Auger electrons. Measurements of concentrations were carried out on scribed samples of cobalt, vanadium, iron and copper silicides, and lead telluride. On the basis of a comparison of the known bulk concentrations and the calculated values, an expression has been chosen for calculating the escape depth of the Auger electrons that gives the best results.

References

18