BMC Genomics · 2008 · 65 citations · 29 references
Life SciencesGeneticsOncologyCancer GeneticsGenomicsMolecular OncologyCancer GenomicsComparative Genomic HybridizationCopy Number AlterationsCopy Number Variant AnalysisGenotyping PlatformsMolecular Tumor ProfilingArray Comparative Genomic HybridizationBreast Cancer GenomicsBreast Tumor ClassificationChromosomal Copy Number AberrationsCluster AnalysisCopy Number ChangesMalignant Breast TumorsStatistical Methods For Validation
BACKGROUND: Microarray Comparative Genomic Hybridization (array CGH) provides a means to examine DNA copy number aberrations. Various platforms, brands and underlying technologies are available, facing the user with many choices regarding platform sensitivity and number, localization, and density distribution of probes. RESULTS: We evaluate three different platforms presenting different nature and arrangement of the probes: The Agilent Human Genome CGH Microarray 44 k, the ROMA/NimbleGen Representational Oligonucleotide Microarray 82 k, and the Illumina Human-1 Genotyping 109 k BeadChip, with Agilent being gene oriented, ROMA/NimbleGen being genome oriented, and Illumina being genotyping oriented. We investigated copy number changes in 20 human breast tumor samples representing different gene expression subclasses, using a suite of graphical and statistical methods designed to work across platforms. Despite substantial differences in the composition and spatial distribution of probes, the comparison revealed high overall concordance. Notably however, some short amplifications and deletions of potential biological importance were not detected by all platforms. Both correlation and cluster analysis indicate a somewhat higher similarity between ROMA/NimbleGen and Illumina than between Agilent and the other two platforms. The programs developed for the analysis are available from http://www.ifi.uio.no/bioinf/Projects/. CONCLUSION: We conclude that platforms based on different technology principles reveal similar aberration patterns, although we observed some unique amplification or deletion peaks at various locations, only detected by one of the platforms. The correct platform choice for a particular study is dependent on whether the appointed research intention is gene, genome, or genotype oriented.
29
Genome-wide analysis of DNA copy-number changes using cDNA microarrays
Jonathan R. Pollack, Charles M. Perou, Ash A. Alizadeh et al. · Nature Genetics · 1999 · 1.4K citations · Full text
Assembly of microarrays for genome-wide measurement of DNA copy number
Antoine M. Snijders, Norma J. Nowak, Richard Segraves et al. · Nature Genetics · 2001 · 1K citations