Metrology and Measurement Systems · 2013 · 12 citations · 10 references
Natural SciencesNuclear EngineeringPhysicsInstrumentationNuclear InstrumentationParticle PhysicsCharged Particle DetectionCollider PhysicsHeavy-ion PhysicsParticle DetectorsCommissioningDetector Timing ResolutionDigitizationDrift ChambersTime ResolutionTiming Resolution
Abstract In the external target experiment for heavy ion collisions in the HIRFL-CSR, Multi-Wire Drift Chambers are used to measure the drift time of charged particles to obtain the track information. This 128-channel high precision time measurement module is designed to perform the time digitization. The data transfer is based on a PXI interface to guarantee a high data rate. Test results show that a 100 ps resolution with a data transfer rate up to 40 MBps has been achieved; this module has also been proven to function well with the detector through a commissioning test.
10
Full-speed testing of A/D converters
J. Doernberg, H.-S. Lee, D.A. Hodges · IEEE Journal of Solid-State Circuits · 1984 · 517 citations
The heavy ion cooler-storage-ring project (HIRFL-CSR) at Lanzhou
Wenlong Zhan, Youjin Yuan, M. T. Song et al. · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2002 · 446 citations
Engineering, Electrical Engineering, Nuclear Engineering +11
Studies of d <i>E</i> /d <i>x</i> measurements with the BESIII
X. B. Ji, Xiang Ma, Ye Yuan et al. · Chinese Physics C · 2010 · 57 citations