Clinical Implant Dentistry and Related Research · 2013 · 79 citations · 22 references
DentistryDental Materials ScienceImplant DentistryDental MaterialsProsthodontic BiomaterialsProsthodontic MaterialsAbutment DesignComputer-aided Implant DesignDental CeramicsImplant DesignImplant MaterialsMaterials For Maxillofacial ProsthesesBondingImplant Abutment MaterialsRetentive StrengthTitanium AbutmentsZirconiaZirconia AbutmentsZirconia CeramicsZirconia Implants
PURPOSE: The purpose of this study is to evaluate the retention of two-piece computer-aided design (CAD)/computer aided manufacturing (CAM) zirconia abutments after artificial aging under simulated oral conditions using three different types of resin-based luting agents. MATERIAL AND METHODS: Twenty-one CAD/CAM-generated zirconia copings (CERCON Compartis, Degudent, Hanau, Germany) were bonded to a prefabricated secondary titanium implant insert (XiVE Ti-Base, Dentsply Friadent, Mannheim, Germany), using three different types of resin-based luting agents: group A: Panavia 21 (Kuraray Co, Kurashiki, Japan); group B: Multilink Implant (Ivoclar Vivadent, Schaan, Liechtenstein); and group C: SmartCem2 (Dentsply DeTrey, Konstanz, Germany). The bonding surfaces of the titanium inserts and the zirconia ceramic copings were air-abraded and cleaned in alcohol. All specimens were stored in distilled water for 60 days and subsequently thermal-cycled 15,000 times (5-55 °C). The dislodging force of the copings along the long axis of the implant/abutment complex was recorded using a universal testing machine with 2 mm/min crosshead speed. Data were analyzed descriptively and by performing the Kruskal-Wallis test. RESULTS: The mean retention values were 924.93 ± 363.31 N for Panavia 21, 878.05 ± 208.33 N for Multilink Implant, and 650.77 ± 174.92 N for SmartCem2. The Kruskal-Wallis test indicated no significant difference between the retention values of the tested luting agents (p = 0.1314). The failure modes of all tested two-piece abutments were completely adhesive, leaving the detached zirconia coping and titanium insert undamaged. CONCLUSION: The use of resin-based luting agents in combination with air abrasion of titanium inserts and zirconia copings led to a stable retention of two-piece CAD/CAM abutments. The bonding stability of the investigated luting agents exceeded the general limits of fracture resistance of two-piece zirconia abutments. A notable difference between the mean retention values of the tested bond materials was shown. However, the statistical analysis revealed that this difference was not significant.
22
The mucosal attachment at different abutments
Ingemar Abrahamsson, Tord Berglundh, P.‐O. Glantz et al. · Journal Of Clinical Periodontology · 1998 · 385 citations · Full text
Dentistry, Dental Biomaterials Science, Implant Dentistry +13
Long-term resin bond strength to zirconia ceramic.
Stefan Martin Wegner, Matthias Kern · PubMed · 2000 · 346 citations
Natural Sciences, Materials Engineering, Materials Science +17
Marco Degidi, Luciano Artese, Antônio Scarano et al. · Journal of Periodontology · 2006 · 295 citations