European Heart Journal · 2012 · 453 citations · 24 references
MedicineCardiologyRadiologyClinical CardiologyDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiovascular ImagingCoronary AngiographyCoronary Artery DiseaseMagnetic Resonance ImagingMyocardial Perfusion ImagingCardiac Myocardial Perfusion ImagingComparative Diagnostic PerformanceConventional AngiographyCoronary Artery Disease ImagingCoronary Ct AngiographyMagnetic ResonanceMyocardial Perfusion ScintigraphyReference Standard Comparison
AIMS: Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. METHODS AND RESULTS: In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. CONCLUSION: In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.
24
Heart Disease and Stroke Statistics—2011 Update
Véronique L. Roger, Alan S. Go, Donald M. Lloyd‐Jones et al. · Circulation · 2010 · 6.2K citations
Heart Disease and Stroke Statistics—2009 Update
Donald M. Lloyd‐Jones, Robert J. Adams, Mercedes R. Carnethon et al. · Circulation · 2008 · 3.1K citations · Full text
Reporting of Noninferiority and Equivalence Randomized Trials
Gilda Piaggio, Diana R Elbourne, Stuart Pocock et al. · JAMA · 2012 · 2.4K citations
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention—Summary Article
Sidney C. Smith, Ted Feldman, John W. Hirshfeld et al. · Circulation · 2006 · 2.2K citations
Medicine, Cardiology, Surgery +13
Guidelines for Percutaneous Coronary Interventions
Sigmund Silber, Per Albertsson, Francisco Fernández‐Avilés et al. · European Heart Journal · 2005 · 1.6K citations · Full text