IEEE Transactions on Industry Applications · 2009 · 30 citations · 5 references
EngineeringElectrical EngineeringEnergy SystemsPerformance MeasurementPower ElectronicsCalibrationCalorimetryDevice CharacterizationElectrical MeasurementLoss AssessmentPower DissipationBallastEnergy MeasurementFluorescent LampsLampsLoss AnalysisPower Loss EstimationPower Loss MeasurementPower Measurement
The direct measurement of losses in power electronic systems is possible through the use of a calorimeter. An improved and fully automated version of a double-jacketed closed-type calorimeter is described in this paper. The accuracy of the calorimeter has been confirmed by calibration tests and is better than 0.1 W in 25 W. The losses in mobile (cell phone) chargers and the ballasts of compact fluorescent lamps have been measured in this calorimeter and are compared to those obtained from conventional measurement methods.
5
An apparatus for loss measurement of integrated power electronics modules: design and analysis
Gang Chen, Chucheng Xiao, W.G. Odendaal · Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344) · 2003 · 29 citations
Engineering, Electrical Engineering, Mechanical Engineering +17