European Journal of Cardio-Thoracic Surgery · 2013 · 23 citations · 22 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyMedical RoboticsEndovascular SurgeryRobot-assisted SurgeryRobotic Cardiothoracic SurgeryRobotic Catheter NavigationSurgical RoboticsTranscatheter Valve TherapyAortic Arch DiseaseCatheter GuidanceFluoroscopy-guided AccessRobot-assisted Catheter ManipulationRobot-assisted Endovascular NavigationRobotic CathetersRobotic Endovascular InterventionRobotic Transcatheter Procedures
OBJECTIVES: The use of transcatheter aortic valve implantation (TAVI) is rapidly increasing with advances in technology and improved clinical outcomes. Adoption of robotic catheter technologies could have a role in TAVI, in different stages of the procedure, to improve endovascular tool manipulation and potentially reduce the risk of cerebral embolization. The aim was to determine whether there are advantages in using a robotic catheter for TAVI in the initial stages of the procedure; aortic arch navigation and valve crossing. METHODS: A silicone in vitro model of the aorta and stenotic aortic valve was developed. Fifteen operators performed the fluoroscopy-guided simulation using manual and robotic techniques. Performance metrics-time and vessel wall contact (wall-hits) were compared (Wilcoxon's signed-rank test). RESULTS: Overall, the time taken for robotic arch navigation was increased (3.09 min interquartile range (1.24-6.29) vs 1.21 min (0.15-4.42); P = 0.03). Contact with the aortic arch wall, however, significantly decreased using the robotic catheter: wall-hits 1 (0-5) vs 6 (2-22), P < 0.01. For valve crossing, there was no significant increase in time and wall-hits when using the robotic technology. CONCLUSIONS: Use of robotic catheter technology is feasible in the initial stages of TAVI. Although it takes longer, robotic navigation reduces contact with the aortic arch wall, potentially reducing the embolic risk during endovascular manipulation. Using a robotic catheter is possible without increasing the number of wall-hits during valve crossing. This may provide a stable platform for wire positioning in the ventricle. With improvements in technology, perhaps allowing valve deployment, the stability and accuracy of the robotic arm may further improve performance.
22
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Craig R. Smith, Martin B. Leon, Michael J. Mack et al. · New England Journal of Medicine · 2011 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +13
Silent Brain Infarcts and the Risk of Dementia and Cognitive Decline
Sarah E. Vermeer, Niels D. Prins, Tom den Heijer et al. · New England Journal of Medicine · 2003 · 2.3K citations · Full text
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Susheel Kodali, Mathew Williams, Craig R. Smith et al. · New England Journal of Medicine · 2012 · 2.3K citations · Full text
Medicine, Cardiology, Surgery +17
Transcatheter Versus Surgical Aortic-Valve Replacement in High-Risk Patients
Craig R. Smith, Martin B. Leon, Michael J. Mack et al. · Survey of Anesthesiology · 2012 · 645 citations
Medicine, Cardiology, Surgery +13