Journal of Endovascular Therapy · 2011 · 41 citations · 18 references
MedicineCardiologySurgeryBiocompatibilityBiomaterialsInterventional CardiologyCardiovascular BiomaterialsImplant MaterialsImplantable BiomaterialsStent PlacementBiocorrosionBiocorrosion MechanismsBiodegradation MechanismsIntimal HyperplasiaMagnesium AlloysRestenosis After StentingStent BiomaterialsVascular Healing
PURPOSE: To determine the efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents (SEBMAS) in restenosis prevention. METHODS: A balloon-expandable bioabsorbable magnesium alloy stent (BMAS) was created and coated with biodegradable poly(lactic acid-co-trimethylene carbonate) that contained the antiproliferative drug sirolimus (140 ± 40 µg/cm²). Both the uncoated BMAS and the coated SEBMAS were deployed 2 cm apart in balloon-injured infrarenal abdominal aortas of 20 New Zealand white rabbits. The stented aortic segments were removed at 30, 60, 90, and 120 days (5 rabbits per interval) after implantation. The average stent strut sectional area of each group was measured to evaluate the degree of magnesium corrosion and to forecast the biodegradation time profile of the magnesium stent. Histology and histopathology of the sectioned stented aortic segments were performed to evaluate neointima formation, endothelialization, and inflammation. RESULTS: The SEBMAS degraded gradually after being implanted into the rabbit aorta, and total biocorrosion occurred after ~120 days. In all groups, the lumen area was significantly greater, but the neointimal area was significantly smaller in SEBMAS segments compared with the uncoated BMAS segments (p < 0.05) at all time points. There was no significant difference in the injury or inflammation scores between the groups. Endothelialization was delayed at 30 days in the SEBMAS segments vs. the uncoated BMAS segments. CONCLUSION: SEBMAS further reduces intimal hyperplasia and improves the lumen area when compared to uncoated BMAS; however, it delays vascular healing and endothelialization.
18
Pathology of Drug-Eluting Stents in Humans
Michael Joner, Aloke V. Finn, Andrew Farb et al. · Journal of the American College of Cardiology · 2006 · 2.7K citations
Medicine, Cardiology, Pathology +11
Willem J. van der Giessen, A. Michael Lincoff, Robert S. Schwartz et al. · Circulation · 1996 · 853 citations · Full text
Natural Sciences, Bioengineering, Biomedical Engineering +17
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
B Heublein · Heart · 2003 · 802 citations · Full text