PLoS ONE · 2014 · 91 citations · 44 references
MedicinePeriodontologyBiomaterialsOrthopaedic BiomaterialsOrthopedic BiomaterialsBiofilm FormationBiofilm Formation In InfectionImplant MaterialsImplant-associated InfectionMetallic BiomaterialsOrthopedic InfectionBacterial Adhesion To Implant SurfacesCobalt-chromium AlloysImplant-associated BiofilmsMicrobiology Of Implant-associated InfectionOrthopaedic ImplantsOrthopedic Implant BiofilmStaphylococcal Implant InfectionStaphylococcal Infections Around Implants
Biofilms forming on the surface of biomaterials can cause intractable implant-related infections. Bacterial adherence and early biofilm formation are influenced by the type of biomaterial used and the physical characteristics of implant surface. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis, the main pathogen in implant-related infections, to form biofilms on the surface of the solid orthopaedic biomaterials, oxidized zirconium-niobium alloy, cobalt-chromium-molybdenum alloy (Co-Cr-Mo), titanium alloy (Ti-6Al-4V), commercially pure titanium (cp-Ti) and stainless steel. A bacterial suspension of Staphylococcus epidermidis strain RP62A (ATCC35984) was added to the surface of specimens and incubated. The stained biofilms were imaged with a digital optical microscope and the biofilm coverage rate (BCR) was calculated. The total amount of biofilm was determined with the crystal violet assay and the number of viable cells in the biofilm was counted using the plate count method. The BCR of all the biomaterials rose in proportion to culture duration. After culturing for 2-4 hours, the BCR was similar for all materials. However, after culturing for 6 hours, the BCR for Co-Cr-Mo alloy was significantly lower than for Ti-6Al-4V, cp-Ti and stainless steel (P<0.05). The absorbance value determined in the crystal violet assay and the number of viable cells on Co-Cr-Mo were not significantly lower than for the other materials (P>0.05). These results suggest that surface properties, such as hydrophobicity or the low surface free energy of Co-Cr-Mo, may have some influence in inhibiting or delaying the two-dimensional expansion of biofilm on surfaces with a similar degree of smoothness.
44
Estimation of the surface free energy of polymers
D.K. Owens, R. C. Wendt · Journal of Applied Polymer Science · 1969 · 9.2K citations
Natural Sciences, Chemistry, Physics +17
Guideline for Prevention of Surgical Site Infection, 1999
Alicia J. Mangram, Teresa Horan, Michele L. Pearson et al. · American Journal of Infection Control · 1999 · 2.9K citations
Medicine, Microbiology, Surgery +17
Alicia J. Mangram, Teresa Horan, Michele L. Pearson et al. · PubMed · 1999 · 2.8K citations
Medicine, Infectious Disease Control, Preventive Medicine +14
Quantification of biofilm structures by the novel computer program comstat
Arne Heydorn, Alex Toftgaard Nielsen, Morten Hentzer et al. · Microbiology · 2000 · 2.2K citations