Physics in Medicine and Biology · 2014 · 40 citations · 31 references
Veterinary MedicineBiomedical EngineeringRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingChest RadiographyChest RadiologyComputed TomographyRadiographic ImagingThoracic RadiographyX-ray DetectorsFlat-panel Detector SystemsFlat-panel DetectorsRadiation Detection SensitivityX-ray Imaging PerformanceX-ray Imaging PhysicsX-ray Imaging SystemsX-ray Source CharacterizationX-ray Source Focal Spot Size
Chest tomosynthesis is a low-dose, quasi-3D imaging modality that has been demonstrated to improve the detection sensitivity for small lung nodules, compared to 2D chest radiography. The purpose of this study is to investigate the feasibility and system requirements of stationary chest tomosynthesis (s-DCT) using a spatially distributed carbon nanotube (CNT) x-ray source array, where the projection images are collected by electronically activating individual x-ray focal spots in the source array without mechanical motion of the x-ray source, detector, or the patient. A bench-top system was constructed using an existing CNT field emission source array and a flat panel detector. The tube output, beam quality, focal spot size, system in-plane and in-depth resolution were characterized. Tomosynthesis slices of an anthropomorphic chest phantom were reconstructed for image quality assessment. All 75 CNT sources in the source array were shown to operate reliably at 80 kVp and 5 mA tube current. Source-to-source consistency in the tube current and focal spot size was observed. The incident air kerma reading per mAs was measured as 74.47 uGy mAs(-1) at 100 cm. The first half value layer of the beam was 3 mm aluminum. An average focal spot size of 2.5 × 0.5 mm was measured. The system MTF was measured to be 1.7 cycles mm(-1) along the scanning direction, and 3.4 cycles mm(-1) perpendicular to the scanning direction. As the angular coverage of 11.6°-34°, the full width at half maximum of the artifact spread function improved greatly from 9.5 to 5.2 mm. The reconstructed tomosynthesis slices clearly show airways and pulmonary vascular structures in the anthropomorphic lung phantom. The results show the CNT source array is capable of generating sufficient dose for chest tomosynthesis imaging. The results obtained so far suggest an s-DCT using a distributed CNT x-ray source array is feasible.
31
Field Emission and Field Ionization.
Robert S. Knox · Journal of the American Chemical Society · 1961 · 825 citations
A comparison of reconstruction algorithms for breast tomosynthesis
Tao Wu, Richard H. Moore, Elizabeth A. Rafferty et al. · Medical Physics · 2004 · 319 citations