EngineeringBiophysicsPhysiologyBiomedical OpticsBiophotonicsCell BiophysicsHemodynamicsLight-tissue InteractionMicrocirculatory PerfusionMicrocirculatory PhysiologyMicrocirculatory TransportOxygen TransportDirect Oxygen Consumption MeasurementExcitationMesenteric VasculatureMicrocirculatory Oxygen TransportMicrovascular Blood FlowMicrovascular HemodynamicsRespiration Rate MeasurementTissue Oxygenation Measurement
In phosphorescence quenching microscopy (PQM), the multiple excitation of a reference volume produces the integration of oxygen consumption artifacts caused by individual flashes. We analyzed the performance of two types of PQM instruments to explain reported data on Po2 in the microcirculation. The combination of a large excitation area (LEA) and high flash rate produces a large oxygen photoconsumption artifact manifested differently in stationary and flowing fluids. A LEA instrument strongly depresses Po2 in a motionless tissue, but less in flowing blood, creating an apparent transmural Po2 drop in arterioles. The proposed model explains the mechanisms responsible for producing apparent transmural and longitudinal Po2 gradients in arterioles, a Po2 rise in venules, a hypothetical high respiration rate in the arteriolar wall and mesenteric tissue, a low Po2 in lymphatic microvessels, and both low and uniform tissue Po2. This alternative explanation for reported paradoxical results of Po2 distribution in the microcirculation obviates the need to revise the dominant role of capillaries in oxygen transport to tissue. Finding a way to eliminate the photoconsumption artifact is crucial for accurate microscopic oxygen measurements in microvascular networks and tissue. The PQM technique that employs a small excitation area (SEA) together with a low flash rate was specially designed to avoid accumulated oxygen photoconsumption in flowing blood and lymph. The related scanning SEA instrument provides artifact-free Po2 measurements in stationary tissue and motionless fluids. Thus the SEA technique significantly improves the accuracy of microscopic Po2 measurements in the microcirculation using the PQM.
60
Mechanisms of Photosensitized Oxidation
Christopher S. Foote · Science · 1968 · 773 citations
Exponential analysis in physical phenomena
A. A. Istratov · Review of Scientific Instruments · 1999 · 613 citations
Annals of Internal Medicine · 1971 · 467 citations
Life Sciences, Physiology, Zoology +16
Longitudinal Gradients in Periarteriolar Oxygen Tension
Brian R. Duling, Robert M. Berne · Circulation Research · 1970 · 466 citations
Life Sciences, Physiology, Zoology +12