IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2004 · 26 citations · 22 references
EngineeringPhysicsMicrowave EngineeringOpticsPhotonicsAtomic ClocksMicrowave MeasurementsMicrowave ResonatorsLong-term StabilityMetallic Thin FilmsMicrowave Atomic ClocksResonant FrequencyResonant Frequency MeasurementResonator Quality FactorThin Film Stability
Slow variations in cavity-Q and microwave power are thought to play a role in the long-term frequency stability of gas-cell atomic clocks. Here, we use an atomic-candle method to study the aging of a TE011 microwave cavity's resonant frequency and quality factor when a glass resonance cell containing Rb87 loads the cavity. Our results suggest that the alkali vapor coats the inside glass surface of the resonance cell with a thin metallic film; and that, as this film evolves, the quality factor degrades. (In our experiments the quality factor changed by approximately 30% over a timescale of months.) More generally, the present work demonstrates the efficacy of the atomic-candle method for investigating cavity resonances. In particular, we show that, when used in conjunction with more traditional methods, the atomic-candle method has the potential to reveal information on a cavity mode's spatial profile.
22
W. Happer · Reviews of Modern Physics · 1972 · 1.7K citations
The Effect of Collisions upon the Doppler Width of Spectral Lines
R. H. Dicke · Physical Review · 1953 · 1.5K citations
DAVID A. DUNNETT · Nature · 1969 · 1.2K citations · Full text