Natural SciencesChemistryBiophotonicsBiosensorsSpectroscopyBioterrorism DetectionLaser SpectroscopyOptical SpectroscopySignal DetectionSpectral SensitivityChemical Attack DetectionDetectionHigh-sensitivity AssaysOptical DetectionPhotoacoustic SpectroscopyQuantum Cascade LasersTerrorist AttackThreshold-based Detection
The need for the detection of chemical warfare agents (CWAs) is no longer confined to battlefield environments because of at least one confirmed terrorist attack, the Tokyo Subway [Emerg. Infect. Dis. 5, 513 (1999)] in 1995, and a suspected, i.e., a false-alarm of a CWA in the Russell Senate Office Building [Washington Post, 9 February 2006, p. B01]. Therefore, detection of CWAs with high sensitivity and low false-alarm rates is considered an important priority for ensuring public safety. We report a minimum detection level for a CWA simulant, dimethyl methyl phosphonate (DMMP), of <0.5 ppb (parts in 10(9)) by use of a widely tunable external grating cavity quantum cascade laser and photoacoustic spectroscopy. With interferents present in Santa Monica, California street air, we demonstrate a false-alarm rate of 1:10(6) at a detection threshold of 1.6 ppb.
9
High-sensitivity detection of TNT
Michael Pushkarsky, Ilya Dunayevskiy, Manu Prasanna et al. · Proceedings of the National Academy of Sciences · 2006 · 209 citations · Full text
Natural Sciences, Chemistry, Physics +16
Aum Shinrikyo: Once and Future Threat?
Emerging infectious diseases · 1999 · 174 citations · Full text