European Journal of Cardio-Thoracic Surgery · 2011 · 31 citations · 6 references
MedicineRadiologySurgeryDiagnostic ImagingDiagnostic RadiologyMedical Visualization3D Imaging3D ReconstructionComputed TomographyMedical ImagingThree-dimensional ReconstructionThree-dimensional Visualization3D Image AnalysisMedical 3D VisualizationThree-dimensional Image ReconstructionThree-dimensional Medical ImagingThree-dimensional Medical VisualizationTomographic Imaging Systems
OBJECTIVES: Several types of practical three-dimensional (3D) imaging software programs are available, including those attached to computed tomographic devices. Three different software programs (Advantage Workstation Volume Share 4, OsiriX and CTTRY) were used to generate 3D images on the basis of imaging data obtained by 64-slice multidetector-row computed tomography in the same patient. METHODS: Surgery was then performed referring to these 3D images in five patients. The characteristics, advantages, disadvantages and utility in the operative field of the images generated with each software program were compared with respect to actual operative findings. RESULTS: There were no marked differences in vascular images at the segmental level among the software programs, and all three were considered useful for surgery. However, vascular images at the subsegmental level differed among the three programs. CONCLUSIONS: The depiction of blood vessels at the subsegmental level lacked accuracy when compared with operative findings.
6
Kenjiro Fukuhara, Akinori Akashi, Shigeru Nakane et al. · European Journal of Cardio-Thoracic Surgery · 2008 · 111 citations · Full text