American Journal of Clinical Pathology · 2006 · 50 citations · 13 references
MedicineHematologyClinical EpidemiologyPatient SafetyTransfusion MedicineBlood Transfusion ManagementBlood Transfusion SafetyBlood TypingTransfusion ReactionsTransfusion TherapyAbo Blood Group TypingBlood Group Incompatibility ManagementBlood Type MatchingTransfusion Error PreventionTransfusion Quality AssuranceTransfusion Reaction Prevention
To detect miscollected (wrong blood in tube [WBIT]) samples, our institution requires a second independently drawn sample (check-type [CT]) on previously untyped, non-group O patients who are likely to require transfusion. During the 17-year period addressed by this report, 94 WBIT errors were detected: 57% by comparison with a historic blood type, 7% by the CT, and 35% by other means. The CT averted 5 potential ABO-incompatible transfusions. Our corrected WBIT error rate is 1 in 3,713 for verified samples tested between 2000 and 2003, the period for which actual number of CTs performed was available. The estimated rate of WBIT for the 17-year period is 1 in 2,262 samples. ABO-incompatible transfusions due to WBIT-type errors are avoided by comparison of current blood type results with a historic type, and the CT is an effective way to create a historic type.
13
A report of 104 transfusion errors in New York State
Jeanne V. Linden, B Paul, K.P. Dressler · Transfusion · 1992 · 329 citations
An international study of the performance of sample collection from patients
Michael Murphy, G. Andreu, Nancy M. Heddle et al. · Vox Sanguinis · 2003 · 151 citations
Reporting of near‐miss events for transfusion medicine: improving transfusion safety
Jeannie Callum, Harold S. Kaplan, Lisa L. Merkley et al. · Transfusion · 2001 · 123 citations
Medicine, Hematology, Patient Safety +16
Analysis of ABO discrepancies occurring in 35 French hospitals
Jacques Chiaroni, D. Legrand, Isabelle Dettori et al. · Transfusion · 2004 · 76 citations