Biomedical Papers · 2004 · 13 citations · 3 references
MedicineNephrologySurgeryDialysisHemodialysisRenal Replacement TherapyHemodialysis ComplicationsHemodynamicsRenal Vascular DiseaseVenous DiseaseBlood FlowHemodynamic PathophysiologyHypertension PathophysiologyRenal Vasculature
The function of an arteriovenous (av) fistula for haemodialysis may be complicated by manifestation of peripheral venous hypertension, which results from the arterial blood flow through the venous system into the periphery of the upper extremity. Its development is most typically caused by a proximal forearm av-fistula, as, in addition to the desirable arterialisation of the subcutaneous venous system of the arm, arterialisation of the venous system of the forearm and the hand may occur and possibly promote the development of venous hypertension, which may in the extreme result in gangrene of the fingers. Awareness of these problems as well as of the necessity of their surgical solution is essential for doctors dealing with haemodialysis.
3
Proximal forearm fistula for maintenance hemodialysis
Kenneth C. Gracz, Todd S. Ing, L. S. Soung et al. · Kidney International · 1977 · 174 citations · Full text
Complications of Arteriovenous Fistulas for Hemodialysis
Moshe Haimov · Archives of Surgery · 1975 · 134 citations
Medicine, Nephrology, Surgery +9