American Industrial Hygiene Association Journal · 1974 · 60 citations · 3 references
Natural SciencesChemical EngineeringChemistryAir PollutionAnalytical ChemistryChemical KineticsActivated CharcoalAir PollutantsVolatile Organic CompoundsActivated Carbon SorbentsAdsorption PhenomenaBreakthrough CurvesBreakthrough TimeChlorinated SolventsFlame Ionization DetectionVapor PressureWater Vapor Effects
Abstract We have determined the service lives of organic vapor respirator cartridges for 121 solvent vapors and gases including aromatics, alcohols, acetates, alkanes, ketones, amines, and chlorinated materials. We passed the vapor and air mixtures through the cartridges and monitored the downstream concentration with a flame ionization detector (FID). Monitoring continues until the cartridge is completely saturated. We compared breakthrough times to values calculated from the adsorption isotherm and Mecklenburg equation and obtained reasonable agreement. In general, the activated carbon has greater affinity for the less volatile materials. Also, the higher the boiling point of the solvent, the greater is the weight of solvent adsorbed. Water vapor, in general, decreases the amount of solvent vapor adsorbed, especially of the more volatile solvents and those soluble in water. The effect of concentration on breakthrough time was briefly investigated and found to conform to the basic Freundlich equation.
3