EngineeringGeometry-based Finite-element ModelingInterface GeometryBiomedical EngineeringNeurochipSocial SciencesCultured NeuronNeuromorphic EngineeringTemporal InformationElectrochemical InterfaceBio-electronic InterfacesBiophysicsDevice ModelingElectrical ContactElectrical EngineeringMicroelectronicsNeural InterfaceNeurophysiologyComputational NeuroscienceMicrofabricationBioelectronicsNeuronal NetworkElectrophysiologyNeuroscience
The electrical contact between a substrate embedded microelectrode and a cultured neuron depends on the geometry of the neuron-electrode interface. Interpretation and improvement of these contacts requires proper modeling of all coupling mechanisms. In literature, it is common practice to model the neuron-electrode contact using lumped circuits in which large simplifications are made in the representation of the interface geometry. In this paper, the finite-element method is used to model the neuron-electrode interface, which permits numerical solutions for a variety of interface geometries. The simulation results offer detailed spatial and temporal information about the combined electrical behavior of extracellular volume, electrode-electrolyte interface and neuronal membrane.