Annals of Clinical Biochemistry International Journal of Laboratory Medicine · 2012 · 114 citations · 32 references
PharmacyImmunologyBiopharmaceuticsBiosensorsImmunotechnologyAssay ValidationBioanalytical Method ValidationBiomarker AnalysisBowel Function AssessmentEnzyme-linked Immunosorbent AssayImmunoassay AnalysisAnalytical Assay VariabilityAssay Variability AssessmentEnzyme-linked Immunosorbent Assay (Elisa)External Quality InspectionFecal BiomarkersIntestinal Health BiomarkersSample Collection DevicesSample Extraction
BACKGROUND: Faecal calprotectin (f-Cp), a marker of intestinal inflammation, can be used to distinguish between functional and organic bowel disease. F-Cp, following extraction, is commonly quantified using enzyme-linked immunosorbent assays (ELISAs) but there are no data comparing the different f-Cp assays or sample extraction devices. We, therefore, evaluated and compared the performance of the Immunodiagnostik, Bühlmann and Eurospital f-Cp ELISA assays as well as the Roche, Immunodiagnostik and ScheBo Biotech commercial faecal extraction devices. We also briefly report results from a pilot f-Cp external quality assurance (EQA) scheme. METHODS: Imprecision, linearity, recovery, drift and limit of quantitation of the f-Cp assays were evaluated and between-assay variability assessed. The three commercial sample extraction devices were compared with the manual weighing method. Four faecal samples were distributed as part of a pilot EQA scheme to 15 laboratories using quantitative ELISA f-Cp assays. RESULTS: The three f-Cp assays demonstrated adequate intra-/interbatch imprecision, linearity and recovery. The cross-comparison study and EQA data demonstrated that, for the same sample, the Bühlmann assay reports up to 3.8 times higher f-Cp concentrations than the Immunodiagnostik and Eurospital assays. On average, the commercial extraction devices led to a 7.8-28.1% under-recovery of f-Cp in comparison to the manual weighing method. CONCLUSIONS: Laboratories should be aware of the lack of the assay standardization, as demonstrated by the between-assay variability. A comparison between f-Cp concentrations reported by these assays and clinical markers of disease severity is required in order to determine their diagnostic accuracy. The EQA scheme represents the first available programme for f-Cp.
32
Limit of blank, limit of detection and limit of quantitation.
David Armbruster, Terry Pry · PubMed · 2008 · 2.1K citations · Full text
Guidelines for the management of inflammatory bowel disease in adults
M J Carter · Gut · 2004 · 1.1K citations · Full text
Metal Chelation and Inhibition of Bacterial Growth in Tissue Abscesses
Brian D. Corbin, Erin H. Seeley, Andrea Raab et al. · Science · 2008 · 856 citations