Clinical Infectious Diseases · 2000 · 19 citations · 17 references
Public HealthInfectious DiseasesMicrobiologyDiagnostic MicrobiologyMolecular VirologyVirologyAntiretroviral TherapyHiv DiagnosisHiv EpidemiologyHiv TestingInfectious Disease Molecular TestingViral DiagnosticsCd4 Cell Count MonitoringEarly Hiv DiagnosisHiv Nucleic Acid TestingHuman Immunodeficiency Virus TestingLaboratory Diagnosis Of HivMolecular Detection AssaysViral Load AssaysViral Load Assessment
Although human immunodeficiency virus type 1 (HIV-1) infection in the United States has predominantly involved subtype B, increasing global travel is leading to wider dissemination of genetically heterogeneous subtypes. While physicians depend on HIV-1 viral load measurements to guide antiretroviral therapy, commonly used molecular assays may underestimate the viral load of patients with non-B subtypes. Nine patients with non-B subtypes of HIV-1 were identified by physicians who suspected a non-B subtype on the basis of a low or undetectable HIV-1 viral load, by the Amplicor HIV-1 Monitor test, version 1.0, in conjunction with either a declining CD4 cell count or history of travel outside the United States. Use of version 1.5 of the Amplicor HIV-1 Monitor test detected a median HIV-1 viral load that was 2.0 log(10) RNA copies/mL higher than was determined with version 1.0. Clinical management was altered in all cases after diagnosis of a non-B-subtype infection. These cases demonstrate that it is critical for physicians to suspect and diagnose non-B subtypes of HIV-1 so that an assay with reliable subtype performance can be used to guide antiretroviral therapy.
17