American Journal of Physiology-Heart and Circulatory Physiology · 1998 · 552 citations · 10 references
MedicineCardiologyPhysiologyBiomedical Signal ProcessingElectrophysiologyPathophysiologyBiopotential MeasurementCardiac Ion ChannelsCardiac PhysiologyElectrocardiogram AnalysisElectrocardiographyHeart Rate VariabilityElectrocardiographic IntervalsElectrophysiologic EffectsElectrophysiological MeasurementHeart RateHeart Rate Variability MeasurementR-r Interval VariabilityRodent ElectrophysiologyTransgenic Mice
Transgenic mouse models enable evaluation of how altered cardiac ion channel properties affect physiology. An implantable telemetry system recorded beat‑by‑beat ECGs, measuring R‑R and Q‑T intervals from 1‑ to 4‑second averages hourly over 24 h in six FVB mice. Averaging length had little impact, Q‑T scales with the square root of R‑R, and a rate‑corrected Q‑T formula was derived; ketamine markedly increased interval duration and variability, whereas conscious mice showed low Q‑T variability, indicating a sensitive model for detecting Q‑T changes in transgenic mice.
Transgenic mouse models provided a powerful tool to evaluate the physiological significance of altered quantities or characteristics of specific gene products, such as cardiac ion channels. We have developed a system to record and analyze changes in the electrocardiogram in the mouse using an implantable telemetry system. The R-R and Q-T intervals were measured on individual beats and on signal-averaged complexes derived from 1, 2, or 4 s of contiguous data each hour during a 24-h period in three male and three female FVB mice. Duration of averaging had minimal effect on the measured Q-T. The Q-T interval was shown to be related to the square root of the R-R interval, and an appropriate formula for a rate-corrected Q-T interval (Q-T c ) was derived. Ketamine anesthesia was shown to markedly increase duration and variability in R-R, Q-T, and Q-T c intervals. In conscious animals, variability in Q-T was low across animals and over time, suggesting that this should be a sensitive model for detection of changes in the Q-T interval in transgenic mice with ion channel defects.
10
An analysis of the time-relations of electrocardiograms
H. C. Bazett · 1920 · 3.8K citations
Medicine, Cardiology, Physiology +10
In Vivo Cardiac Electrophysiology Studies in the Mouse
Charles I. Berul, Mark Aronovitz, Paul J. Wang et al. · Circulation · 1996 · 227 citations
Medicine, Cardiology, Physiology +17
Barry London, Andreas Jeron, Jun Zhou et al. · Proceedings of the National Academy of Sciences · 1998 · 176 citations
Medicine, Cardiology, Genetics +17