Concepedia

Publication | Closed Access

The influence of defects on the short-term breakdown characteristics and long-term dc performance of LDPE insulation

59

Citations

13

References

2000

Year

Abstract

Extruded polyethylene is used as the bulk insulation for ac HV cables because of its high electric resistivity and breakdown strength. Although the material at present has limited use in dc power cables, it is used extensively in submarine optical communication cable systems. This paper reports on the study of the short-term characteristics and long-term performance of low-density polyethylene (LDPE) insulation under dc electric stress. The results are presented in which controlled defects as found in practical systems (voids, metallic and non-metallic particles) were introduced into well-characterized polymer material so that their influence on electrical strength and breakdown mechanisms could be determined. Samples were compression-molded under laboratory conditions and subjected to ramp-to-failure and electrical aging tests at various stresses. Weibull statistics are used to analyze the results. Examination of electrically aged samples indicates an oxidation degradation around the defects due to stress enhancement. From the failed samples a value of n in the inverse power model was estimated. The residual life of aged samples was also examined.

References

YearCitations

Page 1