A <i>R</i><sub>2p</sub>/<i>R</i><sub>1p</sub> Ratiometric Procedure to Assess Matrix Metalloproteinase‐2 Activity by Magnetic Resonance Imaging

Concetta V. Gringeri, Valeria Menchise, Sergio Padovan, Cinzia Boffa, Walter Dastrù, Linda Chaabane, Giuseppe Digilio, Silvio Aime

Angewandte Chemie International Edition · 2013 · 38 citations · 16 references

DOIFull text

Open access

Concepts

Abstract

Parametric MRI: A paramagnetic gadolinium-loaded liposome for the MRI assessment of the activity of matrix metalloproteinase-2 (MMP-2) is described. The assessment relies on a procedure that involves the ratio R2p/R1p between the transverse and longitudinal paramagnetic contributions to the water proton relaxation rate. This method is independent of the total gadolinium concentration. The approach to molecular imaging of enzymes by MRI typically relies upon imaging probes composed of an enzyme-cleavable moiety conjugated with a paramagnetic imaging reporter, such as a GdIII chelate.1 Upon enzymatic processing, the probe is transformed into a fragment with an altered relaxivity, leading to a different capability to enhance contrast in MR images with respect to the parent species. Ideally, the unprocessed (intact) form of the probe should be completely silent while the processed (cleaved) form should have a high relaxivity (that is, high contrast enhancement). In such a way the appearance of contrast within images can be unambiguously attributed to the result of enzymatic activity and not to dynamic changes of tissue probe concentration. However, gadolinium-based agents as enzyme responsive agents are never completely silent and both forms (unprocessed and processed) contribute to the overall contrast enhancement as a function of their respective relaxivities and tissue local concentrations.2 Exact knowledge of the total concentration of Gd is essential to translate image contrast enhancement into the molar ratio of unprocessed versus processed forms, and thus into true enzyme activity maps. A viable solution to the concentration problem can be provided by the R2p/R1p ratiometric approach, which is based on the measurement of the ratio between the transverse and longitudinal paramagnetic contributions to the water proton relaxation rate; that is, R2p and R1p (with Ri=1/Ti, i=1,2). Although ratiometric approaches are well-established for CEST-MRI contrast agents,2, 3 there are only a couple of examples of application to GdIII based relaxation agents, namely for pH and temperature imaging.4, 5 Here, the R2p/R1p ratio is independent from the total concentration of Gd (CT), whereas it only depends on χGdL, defined as the molar ratio of GdL over total gadolinium. Equation (2a) has the form of a rectangular hyperbola. The maximum variation of the R2p/R1p ratio, defined as ΔMAX=(r2GdL/r1GdL−r2GdF/r1GdF), increases with increasing the ratio of the ratios ρ, whereas the term r1GdL/r1GdF affects the shape of the curve (Eq. (2a) reduces to a straight line for r1GdL/r1GdF=1; see Supporting Information S1 for simulations). On the basis of these considerations, we have developed a new system for the ratiometric assessment of the activity of matrix metalloproteinases (MMPs), a family of extracellular matrix (ECM) endoproteases whose expression profile is strongly indicative of pathological conditions, including tumor and neurodegeneration.6 Being MMP extracellular enzymes, either secreted into the ECM or membrane bound ectoenzymes, they have been exploited as targets for molecular imaging of disease by several imaging modalities, including MRI.7, 8 We have synthesized a MMP-2 cleavable probe composed of the NIPVS*LYA sequence, inspired by previous work,9 conjugated with a Gd-DOTA chelate at the N-terminus and with an alkyl chain at the C-terminus (Scheme 1). This amphiphilic probe has been inserted into the membrane of a DPPC/DSPE-PEG stealth liposome (see the Supporting Information), to obtain a paramagnetic vesicle taking the role of species GdL of Equations (1) and (2). Liposome vesicles as carriers for MRI probes offer a number of advantages, including the possibility to achieve high relaxivities and to develop multimodal imaging probes.10, 11 The peptide sequence can be cleaved between Ser and Leu by MMP-2 with release of the soluble GdDOTA-lnk-NIPVS-COOH fragment, which then takes the role of GdF (Scheme 1). Structure and representation of the ratiometric couple GdL/GdF. The dependency of r2 and r1 with the magnetic field for the two members of the ratiometric pair (GdL and GdF) is reported as nuclear magnetic resonance dispersion (NMRD) profiles in Figure 1 a. As can be expected on theoretical grounds, the liposome GdL shows a smooth r1GdL relaxivity peak centered at 20–40 MHz followed by a steep dispersion to 3.7 mM−1 s−1 (at 600 MHz). The relaxivity peak at 20–40 MHz is due to the so-called macromolecule effect, and it is characteristic of systems whose correlation time for molecular reorientation (τR) is slow, as it is the case of gadolinium compounds inserted into liposome membranes.12 The NMRD peak is not as high as it would be expected on the basis of τR typical of liposomes because the rotational flexibility of the peptide chain makes local reorientation motions at the Gd center partly decoupled and faster than global reorientation, with a partial quenching of the macromolecule effect.8, 13 On the other hand, r2GdL remains approximately constant in the 20–600 MHz range, therefore the r2GdL/r1GdL ratio increases with increasing magnetic field. The GdF species (that is, the fragment that is released after MMP-dependent cleavage) presents NMRD features that are in line with those typical of Gd-DOTA-amide compounds of comparable size with a single r1 dispersion. Importantly, the r2GdF relaxivity remains approximately constant in the whole range, but markedly lower than that of the GdL liposome counterpart. a) NMRD profiles (r1 solid symbols; r2 open symbols) of GdL (squares) and GdF (circles) at 25 °C, pH 7.2. b) R2p/R1p versus χGdL plots for mixtures of GdL/GdF measured at the indicated magnetic field (25 °C, pH 7.2). Solid lines are calculated from Equation (2) on the basis of the relaxivities of 1 mM solutions as shown in the NMRD profiles. Ratios were obtained from solutions at CT=1 mM (squares), 500 μM (circles), 250 μM (diamonds) and 125 μM (triangles). Figure 1 a shows the experimentally measured R2p/R1p ratios for a series of samples prepared by mixing different amounts of GdL and GdF while keeping the total concentration of gadolinium fixed at 1 mM. These mixtures approximate a situation in which the GdL liposome is progressively transformed into GdF by MMP-2. As expected (Eq. (2), Figure 1 a), the sensitivity of R2p/R1p to χGdL increases with increasing magnetic field because of an increasing value of ρ. Figure 1 b also shows the same measurements performed with serial dilutions, to ascertain whether R2p/R1p ratios were truly independent from the total Gd concentration CT. At 600 MHz, R2p/R1p versus χGdL plots show a systematic deviation from the ideal behavior with decreasing values of CT. This behavior is explained in terms of a subtle deviation from linearity of the R2pGdL versus [GdL] plot, introducing a residual dependency of R2p/R1p on the total Gd concentration (Eq. (1) no longer holds true). Such a detrimental effect is greatly attenuated at 300 MHz, where R2p/R1p ratios obtained within the CT range 125–1000 μM are truly independent from CT and responsive to χGdL with sensitivity ΔMAX=1.2 (Figure 2). R2p/R1p is responsive to χGdL in a total Gd concentration independent manner down to 125 MHz, but the sensitivity becomes attenuated (ΔMAX=0.6). Thus, the magnetic field of 300 MHz appears to be the best trade-off between sensitivity of R2p/R1p to χGdL and residual dependency of R2p/R1p on total Gd concentration. Therefore, this magnetic field has been selected to see whether our system was suitable to obtain R2p/R1p maps under a MRI setting. R1p and R2p maps of a phantom containing mixtures of GdL and GdF within the CT range 125–1000 μM were acquired at 300 MHz and the corresponding R2p/R1p parametric image was constructed on a pixel-by-pixel basis (Figure 3 a), while a plot of R2p/R1p with error bars as a function of ROI numbering is provided in Figure 3 c. The contrast of the ratiometric map is independent from CT and appears responsive only to χGdL, but the measurement uncertainty of R2p/R1p still shows a dependency on CT. The uncertainty of R2p/R1p is contributed by errors propagating from the four quantities that are required to calculate the ratio (these quantities are R1, R2, R1,dia, R2,dia, where Ri,dia are the baseline relaxation rates, Ri are the relaxation rates observed in the presence of gadolinium, and Rip=Ri−Ri,dia). The uncertainty of R2p/R1p increases when R2p and R1p are small relative to the baseline relaxation rates R2,dia and R1,dia; that is, when CT approaches the detection limit (50 μM in buffer; see the Supporting Information). Although CT does not formally affect the R2p/R1p ratio, it comes back into play by affecting the precision by which R2p/R1p (and thus χGdL) can be measured. Although the uncertainity of R2p/R1p increases with decreasing CT, the difference of the R2p/R1p ratio at χGdL 100 %, and 0 % can still be appreciated at 125 μM. Large baseline relaxation rates (especially R2,dia) can be found in tissue, leading to a negative impact on the sensitivity of the ratiometric method. To better mimic tissue baseline relaxation rates, a number of mixtures of GdL/GdF were dispersed within a 1 % agar matrix and a ratiometric image was acquired (Figure 3 b). As expected, the larger R2,dia of the agar matrix led to larger uncertainties of the R2p/R1p ratio (Figure 3 c). However, the sensitivity of the R2p/R1p ratio to χGdL in agar was greatly enhanced compared to water (ρ=4.8, ΔMAX=7.6). Such a sensitivity enhancement is essentially linked to the increase of r2GdL over r1GdL, r2GdF and r1GdF (Supporting Information, Table S1), because the high microviscosity of the agar matrix slows down the reorientation dynamics of the paramagnetic liposome. As a result, the sensitivity improvement makes up for the negative effects of large baseline R2,dia, and the R2p/R1p ratio remains responsive to the GdL/GdF mixing ratio down to the detection limit (120 μM in 1 % agar). R2p/R1p ratios measured at 300 MHz as a function of CT at five χGdL values: χGdL=0 (▪); 25 % (•); 50 % (⧫); 75 % (▾), and 100 % (▴). Straight lines represent each average ±SD. Pseudo-colored parametric R2p/R1p images obtained at 300 MHz (7 T). a) Water phantom containing an array of 20 mixtures of GdL/GdF with different molar ratios and different CT (25 °C, pH 7.2). Total Gd concentrations: 1 mM (1 to 5), 500 μM (6 to 10), 250 μM (11 to 15), 125 μM (16 to 20). Within each of these series, χGdL is 100, 75, 50, 25, and 0 % with increasing numbering order. Lines connect samples with the same χGdL but different CT. b) 1 % agar phantom containing an array of 12 mixtures GdL/GdF. Wells with the same numbering have the same composition. c) Plot of the R2p/R1p ratio as a function of well number. CT and χGdL are given as label of the x-axis. ▪ agar phantom, • water phantom. Error bars represent ±one SD. Finally we evaluated the feasibility of the ratiometric approach in kinetic experiments by incubating the MMP responsive GdL liposomes with MMP-2 and measuring the change of R2p and R1p as a function of the incubation time. The reaction, as far as followed by the change of R2p with time (300 MHz, 25 °C), is first-order with respect to the substrate up to a substrate concentration of 1.0 mM, allowing for the calculation of kcat/Km=1.9×104 M−1 s−1. The peptide cleavage efficiency of the GdL system is smaller in respect to those reported for other sequences that have been used as MMP-responsive probes,7 which is most likely because of steric hindrance stemming from the insertion of the MMP-2 substrate into the liposome membrane. Figure 4 shows the change of R2p/R1p as a function of incubation time (each point in the graph is the average of kinetic experiments with an initial CT of 230, 450, and 900 μM), showing a substantial independence of the change of R2p/R1p from CT. A ΔMAX of 0.65 is observed in this system, because only a fraction of GdL (for example, that protruding to the outer side of the liposome membrane) is recognized by MMP-2 and transformed into GdF, whereas Gd pointing to the inner liposome water cavity is not affected and introduces an offset contribution to the final observed relaxation rate. Plot of R2p/R1p versus time after incubation of the responsive liposome with MMP-2 (25 °C, pH 7.2, 300 MHz). Average ±SD are shown for ratios measured at CT of 230, 450, and 900 μM. In summary, we have presented a general ratiometric approach to obtain enzyme activity maps by MRI, and have exploited it to implement a novel liposome-based ratiometric couple to detect MMP-2 activity. The proposed method provides a means to evaluate the mixing ratio χGdL between the unprocessed (GdL) and the processed (GdF) form of a ratiometric pair. In principle this parameter can be directly related to the activity of MMP-2 in tissue. However, tissue influx/efflux rates of GdL and GdF are likely to be different, making the ratiometric χGdL dependent upon a function of both MMP activity and pharmacokinetics. To account for pharmacokinetic effects, an empirical calibration curve linking ratiometric χGdL measurements with histochemical/biochemical evaluations of MMP activity is required. Without a proper calibration, this method will not give a quantitative number of enzyme activity, but a relative estimate. The liposome-based MRI reporter is well amenable to combine imaging and therapy in an all-in-one system, eventually providing a theranostic approach to MMP-related pathologies, including cancer.14 Compounds GdL and GdF were synthesized by solid-phase peptide synthesis essentially as described previously.8 Liposomes were made by hydrating a thin film composed of DPPC/Methoxy-DSPE-PEG/GdL 66:9:25 w/w, and sonication to obtain vesicles with typical diameter of 80±20 nm and polydispersity index of 0.2 as measured by DLS. MR images and relaxation rates measurements were carried out with Bruker MRI scanners operating at 125 MHz (3 T) and 300 MHz (7 T). For T1 maps, a RARE-VTR sequence was used with RARE factor=1, 16 TR values from 80 to 15 000 ms, TE 10 ms, NEX 4, FOV=2.6×2.6 cm, matrix 192×192 (spatial resolution 0.135 mm/pixel), slice thickness 2 mm. T2-maps were obtained with a MSME sequence with 32 variable TE (10 to 320 ms), TR 15 000 ms, NEX 4, FOV=2.6×2.6 cm, matrix 192×192 (spatial resolution 0.135 mm/pixel), slice thickness 2 mm. More experimental details can be found the Supporting Information. As a service to our authors and readers, this journal provides supporting information supplied by the authors. Such materials are peer reviewed and may be re-organized for online delivery, but are not copy-edited or typeset. Technical support issues arising from supporting information (other than missing files) should be addressed to the authors. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

References

16