Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?

Stephen M. Howell, Stacey J. Howell, Kyle Kuznik, Joe Cohen, Maury L. Hull

Clinical Orthopaedics and Related Research · 2012 · 484 citations · 24 references

Concepts

TL;DR

Kinematically aligned total knee arthroplasty aligns femoral and tibial components to the joint lines of the knee, but this can place the tibial component in varus, raising concerns about poor function and early catastrophic failure. The study aimed to determine whether function and catastrophic failure rates differed among knees with tibial, knee, and limb alignment in normal range, varus outlier, or valgus outlier categories. In a prospective cohort of 198 patients, a cruciate‑retaining prosthesis was implanted using patient‑specific guides, alignment was categorized from long‑leg scanograms, and function was assessed with Oxford Knee and WOMAC scores while catastrophic failure was defined as revision for loosening, wear, or instability. Across all alignment categories, mean Oxford Knee and WOMAC scores were comparable, catastrophic failure incidence was zero, and 75 % of patients had a varus‑outlier tibial component yet achieved high function, indicating that kinematic alignment restores function without catastrophic failure regardless of alignment. See Guidelines for Authors for a complete description of levels of evidence.

Abstract

Kinematically aligned TKA restores function by aligning the femoral and tibial components to the normal or prearthritic joint lines of the knee. However, aligning the components to the joint lines of the normal knee also aligns the tibial component in varus, creating concern that varus alignment might result in poor function and early catastrophic failure.We therefore determined whether function and the incidence of catastrophic failure were different when the tibial component, knee, and limb alignment were in a specified normal range, varus outlier, or valgus outlier.We prospectively followed all 198 patients (214 knees) who underwent TKAs between February and October 2008. We treated each knee in this cohort of patients with a kinematically aligned, cruciate-retaining prosthesis implanted using patient-specific guides. From a long-leg scanogram, we measured and categorized alignment of the tibial component as in range (≤ 0°) or a varus outlier (> 0°), alignment of the knee as in range (between -2.5° to -7.4° valgus) or a varus (> -2.5°) or valgus (< -7.4°) outlier, and alignment of the limb as in range (0° ± 3°) or a varus (> 3°) or valgus (< -3°) outlier. We assessed function using the Oxford Knee Score and WOMAC score, and reported catastrophic failure as the incidence of revision attributable to loosening, wear, and instability of the femoral or tibial components. The minimum followup was 31 months (mean, 38 months; range, 31-43 months).The mean Oxford Knee Score of 43 and WOMAC score of 92 were similar between the three alignment categories. The incidence of catastrophic failure in each alignment category was zero.Kinematically aligned TKA restores function without catastrophic failure regardless of the alignment category. Because 75% of patients had their tibial component categorized as a varus outlier and also had high function and a zero incidence of catastrophic failure, the concern that kinematic alignment compromises function and places the components at a high risk for catastrophic failure is unfounded and should be of interest to surgeons committed to cutting the tibia perpendicular to the mechanical axis of the tibia.Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

References

24